Skip to content

Prices for registered businessesRegister

CopperCoreCOPPERCORE

NSGAFöU

Rubber-sheathed single-core cable 1,8/3 kV (NSGAFöU), short-circuit and earth-fault proof up to 1000 V, oil resistant, for increased mechanical stress.

Download datasheet (PDF)
Rubber-sheathed single-core cable 1,8/3 kV (NSGAFöU), short-circuit and earth-fault proof up to 1000 V, oil resistant, for increased mechanical stress.

Variants

SECTION (mm²)1×1,5APPROX. (AWG)16OUTER Ø MIN-MAX (mm)5,1 – 7,0COPPER WT. (kg/km)14,4CABLE WT. (kg/km)65,0Availability
On request
SECTION (mm²)1×2,5APPROX. (AWG)14OUTER Ø MIN-MAX (mm)5,6 – 7,5COPPER WT. (kg/km)24,0CABLE WT. (kg/km)80,0Availability
On request
SECTION (mm²)1×4APPROX. (AWG)12OUTER Ø MIN-MAX (mm)6,2 – 9,0COPPER WT. (kg/km)38,0CABLE WT. (kg/km)95,0Availability
On request
SECTION (mm²)1×6APPROX. (AWG)10OUTER Ø MIN-MAX (mm)6,7 – 9,5COPPER WT. (kg/km)58,0CABLE WT. (kg/km)110,0Availability
On request
SECTION (mm²)1×10APPROX. (AWG)8OUTER Ø MIN-MAX (mm)8,1 – 11,0COPPER WT. (kg/km)96,0CABLE WT. (kg/km)165,0Availability
On request
SECTION (mm²)1×16APPROX. (AWG)6OUTER Ø MIN-MAX (mm)9,1 – 13,0COPPER WT. (kg/km)154,0CABLE WT. (kg/km)235,0Availability
On request
SECTION (mm²)1×25APPROX. (AWG)4OUTER Ø MIN-MAX (mm)11,1 – 15,0COPPER WT. (kg/km)240,0CABLE WT. (kg/km)360,0Availability
On request
SECTION (mm²)1×35APPROX. (AWG)2OUTER Ø MIN-MAX (mm)12,3 – 16,5COPPER WT. (kg/km)336,0CABLE WT. (kg/km)460,0Availability
On request
SECTION (mm²)1×50APPROX. (AWG)1OUTER Ø MIN-MAX (mm)13,8 – 18,0COPPER WT. (kg/km)480,0CABLE WT. (kg/km)620,0Availability
On request
SECTION (mm²)1×70APPROX. (AWG)2/0OUTER Ø MIN-MAX (mm)15,5 – 20,5COPPER WT. (kg/km)672,0CABLE WT. (kg/km)820,0Availability
On request
SECTION (mm²)1×95APPROX. (AWG)3/0OUTER Ø MIN-MAX (mm)17,7 – 24,0COPPER WT. (kg/km)912,0CABLE WT. (kg/km)1070,0Availability
On request
SECTION (mm²)1×120APPROX. (AWG)4/0OUTER Ø MIN-MAX (mm)19,2 – 26,0COPPER WT. (kg/km)1152,0CABLE WT. (kg/km)1330,0Availability
On request
SECTION (mm²)1×150APPROX. (AWG)300 kcmilOUTER Ø MIN-MAX (mm)21,1 – 28,0COPPER WT. (kg/km)1440,0CABLE WT. (kg/km)1620,0Availability
On request
SECTION (mm²)1×185APPROX. (AWG)350 kcmilOUTER Ø MIN-MAX (mm)23,1 – 31,0COPPER WT. (kg/km)1776,0CABLE WT. (kg/km)1960,0Availability
On request
SECTION (mm²)1×240APPROX. (AWG)500 kcmilOUTER Ø MIN-MAX (mm)26,0 – 34,5COPPER WT. (kg/km)2304,0CABLE WT. (kg/km)2570,0Availability
On request
SECTION (mm²)1×300APPROX. (AWG)600 kcmilOUTER Ø MIN-MAX (mm)28,4 – 38,0COPPER WT. (kg/km)2880,0CABLE WT. (kg/km)3180,0Availability
On request

Prices for registered business customers · Registration takes 2 minutes

Sign inRegister

Construction

ConductorCu kalajisan, fina žica, kl.5 / tinned
InsulationGuma EPR, tip 3GI3 (VDE 0207-20)
SheathPolihloropren, tip 5GM3 (VDE 0207-21)
ColourCrna ili narandžasta / black or orange

Technical data

Voltage1,8 / 3 kV
Test voltage6 kV
Max. cond.+90 °C
Mobile-25 … +80 °C
Fixed-40 … +80 °C
Bending10 × D (6 × D fiksno)

Application

For rail vehicles, buses and dry rooms. Short-circuit and earth-fault proof up to 1000 V in switchgear and distribution boards. For pipes, ducts, moving parts and device wiring; not on trays and ladders.

Standards

DIN VDE 0250-602 · EN 60332-1-2 · EN 60811-404

Documents

NSGAFöU · PDF · 340 KBDownload datasheet (PDF)