LV Power Cables
Low-voltage power cables rated up to 0.6/1 kV, with copper or aluminium conductors and PVC or cross-linked (XLPE) insulation. They are laid in the ground, in cable ducts and on trays — for urban distribution networks, industrial plants and power stations. The group is rounded out by armoured, halogen-free and fire-resistant designs for buildings with heightened fire-safety requirements.

Armoured power cable 0,6/1 kV with copper conductors, XLPE insulation, two galvanized steel tape armour and PVC sheath (N2XBY · JUS XP41).

Halogen-free power cable 0,6/1 kV with copper conductors, XLPE insulation, concentric conductor and HFFR sheath (N2XCH).

Halogen-free power cable 0,6/1 kV with copper conductors, XLPE insulation and LSZH sheath (N2XH).

Wire-armoured power cable 0,6/1 kV with stranded copper conductors, XLPE insulation, galvanized steel wire armour and PVC sheath (N2XRY · JUS XP44).

Power cable 0,6/1 kV with copper conductors, XLPE insulation and PVC sheath (N2XY · JUS XP00).

Armoured power cable 0,6/1 kV with aluminium conductors, XLPE insulation, two galvanized steel tape armour and PVC sheath (NA2XBY · JUS XP41-A).

Power cable 0,6/1 kV with aluminium conductors, XLPE insulation and HFFR (LSZH) sheath (NA2XH).

Wire-armoured power cable 0,6/1 kV with aluminium conductors, XLPE insulation, round galvanized steel wire armour and PVC sheath (NA2XRY · JUS XP44-A).

Power cable 0,6/1 kV with aluminium conductors, XLPE insulation and PVC sheath (NA2XY · JUS XP00-A).

Power cable 0,6/1 kV with aluminium conductors, PVC insulation, wave-form concentric conductor and PVC sheath (NAYCWY · JUS PP42-A).

Power cable 0,6/1 kV with stranded aluminium conductor, PVC insulation and concentric copper wire screen (NAYCY · JUS PP40-A).

Power cable 0,6/1 kV with aluminium conductors, PVC insulation and PVC sheath (NAYY · JUS PP00-A).

Halogen-free fire-resistant power cable 0,6/1 kV, cross-linked (ceramifiable) insulation, orange sheath; FE180 and E90 circuit integrity (NHXCH).

Halogen-free power and signal cable 0,6/1 kV with improved properties under fire and 90-minute circuit integrity maintenance (NHXH FE180/E90).

Halogen-free (HFFR/LSZH) power and signal cable (NHXMH), 300/500 V, with improved behaviour under fire.

Power cable 0,6/1 kV with copper conductors, PVC insulation, wave-form concentric conductor and PVC sheath (NYCWY · JUS PP42).

Power cable 0,6/1 kV with copper conductors, PVC insulation, concentric conductor and PVC sheath (NYCY · JUS PP40).

PVC-insulated power cable with flat galvanized steel-wire armour and PVC sheath, 0.6/1 kV and 3.6/6 kV (NYFGY, VDE 0271 ≈ JUS PP45).

Wire-armoured power cable 0,6/1 kV with class 2 copper conductors, PVC insulation, galvanized steel wire armour and PVC sheath (NYRY · JUS PP44).

Power cable 0,6/1 kV with copper conductors, PVC insulation and PVC sheath (NYY · JUS PP00).

Halogen-free installation cable 0,6/1 kV with ceramizable (silicone) insulation, improved properties under fire and 90-minute circuit integrity ((N)HXH FRHF FE180/E90).