H07Z1-K
Low-voltage flexible copper conductor with halogen-free HFFR (TI7) insulation (H07Z1-K), class-5 stranded, 450/750 V.
Download datasheet (PDF)
Variants
| SECTION (mm²)1,5 | RESISTANCE (Ω/km)13,3 | CURRENT 2 C. (A)24 | CURRENT 3 C. (A)22 | INSUL. THK. (mm)0,7 | OUTER Ø MIN (mm)2,8 | OUTER Ø MAX (mm)3,4 | METAL WT. (kg/km)14,4 | CABLE WT. (kg/km)22 | Availability On request |
| SECTION (mm²)2,5 | RESISTANCE (Ω/km)7,98 | CURRENT 2 C. (A)33 | CURRENT 3 C. (A)30 | INSUL. THK. (mm)0,8 | OUTER Ø MIN (mm)3,4 | OUTER Ø MAX (mm)4,1 | METAL WT. (kg/km)24,0 | CABLE WT. (kg/km)34 | Availability On request |
| SECTION (mm²)4 | RESISTANCE (Ω/km)4,95 | CURRENT 2 C. (A)45 | CURRENT 3 C. (A)40 | INSUL. THK. (mm)0,8 | OUTER Ø MIN (mm)3,9 | OUTER Ø MAX (mm)4,8 | METAL WT. (kg/km)38,4 | CABLE WT. (kg/km)51 | Availability On request |
| SECTION (mm²)6 | RESISTANCE (Ω/km)3,30 | CURRENT 2 C. (A)58 | CURRENT 3 C. (A)52 | INSUL. THK. (mm)0,8 | OUTER Ø MIN (mm)4,4 | OUTER Ø MAX (mm)5,3 | METAL WT. (kg/km)57,6 | CABLE WT. (kg/km)72 | Availability On request |
| SECTION (mm²)10 | RESISTANCE (Ω/km)1,910 | CURRENT 2 C. (A)80 | CURRENT 3 C. (A)71 | INSUL. THK. (mm)1,0 | OUTER Ø MIN (mm)5,7 | OUTER Ø MAX (mm)6,8 | METAL WT. (kg/km)96,0 | CABLE WT. (kg/km)119 | Availability On request |
| SECTION (mm²)16 | RESISTANCE (Ω/km)1,210 | CURRENT 2 C. (A)107 | CURRENT 3 C. (A)96 | INSUL. THK. (mm)1,0 | OUTER Ø MIN (mm)6,7 | OUTER Ø MAX (mm)8,1 | METAL WT. (kg/km)153,6 | CABLE WT. (kg/km)181 | Availability On request |
| SECTION (mm²)25 | RESISTANCE (Ω/km)0,780 | CURRENT 2 C. (A)138 | CURRENT 3 C. (A)119 | INSUL. THK. (mm)1,2 | OUTER Ø MIN (mm)8,4 | OUTER Ø MAX (mm)10,2 | METAL WT. (kg/km)240,0 | CABLE WT. (kg/km)280 | Availability On request |
| SECTION (mm²)35 | RESISTANCE (Ω/km)0,554 | CURRENT 2 C. (A)171 | CURRENT 3 C. (A)147 | INSUL. THK. (mm)1,2 | OUTER Ø MIN (mm)9,7 | OUTER Ø MAX (mm)11,7 | METAL WT. (kg/km)336,0 | CABLE WT. (kg/km)383 | Availability On request |
| SECTION (mm²)50 | RESISTANCE (Ω/km)0,386 | CURRENT 2 C. (A)209 | CURRENT 3 C. (A)179 | INSUL. THK. (mm)1,4 | OUTER Ø MIN (mm)11,5 | OUTER Ø MAX (mm)13,9 | METAL WT. (kg/km)480,0 | CABLE WT. (kg/km)545 | Availability On request |
| SECTION (mm²)70 | RESISTANCE (Ω/km)0,272 | CURRENT 2 C. (A)269 | CURRENT 3 C. (A)229 | INSUL. THK. (mm)1,4 | OUTER Ø MIN (mm)13,2 | OUTER Ø MAX (mm)16,0 | METAL WT. (kg/km)672,0 | CABLE WT. (kg/km)747 | Availability On request |
| SECTION (mm²)95 | RESISTANCE (Ω/km)0,206 | CURRENT 2 C. (A)328 | CURRENT 3 C. (A)278 | INSUL. THK. (mm)1,6 | OUTER Ø MIN (mm)15,1 | OUTER Ø MAX (mm)18,2 | METAL WT. (kg/km)912,0 | CABLE WT. (kg/km)1012 | Availability On request |
| SECTION (mm²)120 | RESISTANCE (Ω/km)0,161 | CURRENT 2 C. (A)382 | CURRENT 3 C. (A)322 | INSUL. THK. (mm)1,6 | OUTER Ø MIN (mm)16,7 | OUTER Ø MAX (mm)20,2 | METAL WT. (kg/km)1152,0 | CABLE WT. (kg/km)1263 | Availability On request |
| SECTION (mm²)150 | RESISTANCE (Ω/km)0,129 | CURRENT 2 C. (A)441 | CURRENT 3 C. (A)371 | INSUL. THK. (mm)1,8 | OUTER Ø MIN (mm)18,6 | OUTER Ø MAX (mm)22,5 | METAL WT. (kg/km)1440,0 | CABLE WT. (kg/km)1579 | Availability On request |
| SECTION (mm²)185 | RESISTANCE (Ω/km)0,106 | CURRENT 2 C. (A)506 | CURRENT 3 C. (A)424 | INSUL. THK. (mm)2,0 | OUTER Ø MIN (mm)20,6 | OUTER Ø MAX (mm)24,9 | METAL WT. (kg/km)1776,0 | CABLE WT. (kg/km)1948 | Availability On request |
| SECTION (mm²)240 | RESISTANCE (Ω/km)0,0801 | CURRENT 2 C. (A)599 | CURRENT 3 C. (A)500 | INSUL. THK. (mm)2,2 | OUTER Ø MIN (mm)23,5 | OUTER Ø MAX (mm)28,4 | METAL WT. (kg/km)2304,0 | CABLE WT. (kg/km)2519 | Availability On request |
Construction
ConductorBakarno uže, klasa 5 / Cu rope, cl.5
InsulationBez halogena, tip TI7 / HFFR, TI7
UV resistanceDa / Yes (EN 50363-7)
Core IDEN 50525-1
Technical data
Voltage450 / 750 V
Test voltage2,5 kV
CPR classB2ca-s1,d1,a1
Bending5 × D
Max. cond.70 °C
Short-circuit160 °C
Application
For wiring of lamps, devices and switchgear cabinets; installation in tubes, on, in and under plaster and in closed ducts. Halogen-free, low smoke — for buildings with many people or valuable assets.
Standards
EN 50525-3-31 · EN 60754-1/-2 · EN 50575 (CPR)
Documents
H07Z1-K · PDF · 370 KBDownload datasheet (PDF)