JE-H(St)H
Fire-resistant halogen-free signal cable (JE-H(St)H…Bd FE180/PH120) with silicone insulation and orange HFFR sheath.
Download datasheet (PDF)
Variants
| PAIRS × Ø/SECT. (n×2×(mm·mm²))1×2×0,6 | OUTER Ø (mm)4,7 | CABLE WT. (kg/km)27 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))2×2×0,6 | OUTER Ø (mm)5,1 | CABLE WT. (kg/km)36 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))3×2×0,6 | OUTER Ø (mm)6,2 | CABLE WT. (kg/km)49 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))4×2×0,6 | OUTER Ø (mm)6,6 | CABLE WT. (kg/km)58 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))6×2×0,6 | OUTER Ø (mm)7,5 | CABLE WT. (kg/km)76 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))8×2×0,6 | OUTER Ø (mm)8,2 | CABLE WT. (kg/km)93 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))10×2×0,6 | OUTER Ø (mm)9,1 | CABLE WT. (kg/km)110 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))1×2×0,8 | OUTER Ø (mm)5,8 | CABLE WT. (kg/km)43 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))2×2×0,8 | OUTER Ø (mm)6,5 | CABLE WT. (kg/km)61 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))3×2×0,8 | OUTER Ø (mm)8,1 | CABLE WT. (kg/km)83 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))4×2×0,8 | OUTER Ø (mm)8,7 | CABLE WT. (kg/km)99 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))6×2×0,8 | OUTER Ø (mm)10,1 | CABLE WT. (kg/km)133 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))8×2×0,8 | OUTER Ø (mm)11,3 | CABLE WT. (kg/km)168 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))10×2×0,8 | OUTER Ø (mm)13,0 | CABLE WT. (kg/km)213 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))1×2×1,0 | OUTER Ø (mm)6,7 | CABLE WT. (kg/km)56 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))2×2×1,0 | OUTER Ø (mm)7,5 | CABLE WT. (kg/km)82 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))3×2×1,0 | OUTER Ø (mm)9,6 | CABLE WT. (kg/km)115 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))4×2×1,0 | OUTER Ø (mm)10,5 | CABLE WT. (kg/km)143 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))6×2×1,0 | OUTER Ø (mm)12,7 | CABLE WT. (kg/km)206 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))8×2×1,0 | OUTER Ø (mm)14,1 | CABLE WT. (kg/km)258 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))10×2×1,0 | OUTER Ø (mm)15,9 | CABLE WT. (kg/km)314 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))1×2×1,5 | OUTER Ø (mm)7,8 | CABLE WT. (kg/km)78 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))2×2×1,5 | OUTER Ø (mm)8,9 | CABLE WT. (kg/km)122 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))3×2×1,5 | OUTER Ø (mm)11,5 | CABLE WT. (kg/km)172 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))4×2×1,5 | OUTER Ø (mm)13,0 | CABLE WT. (kg/km)229 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))6×2×1,5 | OUTER Ø (mm)15,3 | CABLE WT. (kg/km)316 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))8×2×1,5 | OUTER Ø (mm)17,2 | CABLE WT. (kg/km)406 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))10×2×1,5 | OUTER Ø (mm)19,8 | CABLE WT. (kg/km)512 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))1×2×2,5 | OUTER Ø (mm)8,9 | CABLE WT. (kg/km)105 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))2×2×2,5 | OUTER Ø (mm)10,3 | CABLE WT. (kg/km)172 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))3×2×2,5 | OUTER Ø (mm)13,9 | CABLE WT. (kg/km)261 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))4×2×2,5 | OUTER Ø (mm)15,2 | CABLE WT. (kg/km)328 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))6×2×2,5 | OUTER Ø (mm)18,5 | CABLE WT. (kg/km)481 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))8×2×2,5 | OUTER Ø (mm)20,7 | CABLE WT. (kg/km)614 | Availability On request |
| PAIRS × Ø/SECT. (n×2×(mm·mm²))10×2×2,5 | OUTER Ø (mm)23,9 | CABLE WT. (kg/km)778 | Availability On request |
Reference tables
| Ø / SECTION (mm · mm²)0,6 mm | LOOP RESIST. (Ω/km)130 | TEST VOLTAGE (V DC)500 |
| Ø / SECTION (mm · mm²)0,8 mm | LOOP RESIST. (Ω/km)73,2 | TEST VOLTAGE (V DC)500 |
| Ø / SECTION (mm · mm²)1,0 mm | LOOP RESIST. (Ω/km)44,6 | TEST VOLTAGE (V DC)1000 |
| Ø / SECTION (mm · mm²)1,5 mm² | LOOP RESIST. (Ω/km)24,6 | TEST VOLTAGE (V DC)1000 |
| Ø / SECTION (mm · mm²)2,5 mm² | LOOP RESIST. (Ω/km)15,1 | TEST VOLTAGE (V DC)1000 |
Construction
ConductorCu puna žica, klasa 1 / solid Cu, cl. 1
InsulationSilikonska, boje po VDE 0815 / silicone
Stranding2 parice: četvorka; više: slojevi
WrappingTraka od staklenih vlakana / glass fibre
ScreenAl-PES traka + kalajis. Cu drain žica
SheathHFFR, narandžasti RAL 2008 / orange
Technical data
Operating voltage225 V
Test voltage0,5 / 1 kV DC (1 min)
Capacitance120 nF/km
Operating temp.-30 … +70 °C
Bending radius10 × D
Circuit integrityFE180 / PH120
Application
For densely occupied premises, fire-alarm and security systems, signal transmission, instrumentation and industrial electronics — where circuit integrity in fire is required.
Standards
IEC60331-23
VDE 0815 · IEC 60331-23 · EN 50200 · EN 60332-1-2
Documents
JE-H(St)H · PDF · 4.0 MBDownload datasheet (PDF)