YSLY EB
Intrinsically-safe (“i”) flexible control/measuring cable, PVC-insulated with blue PVC sheath (YSLY-EB), class-5 Cu rope, 300/500 V.
Download datasheet (PDF)
Variants
| CORES × SECTION (n×mm²)2×0,75 | OUTER Ø (mm)5,5 | CABLE WT. (kg/km)42 | COPPER (kg/km)15,0 | Availability On request |
| CORES × SECTION (n×mm²)3×0,75 | OUTER Ø (mm)5,7 | CABLE WT. (kg/km)55 | COPPER (kg/km)22,5 | Availability On request |
| CORES × SECTION (n×mm²)4×0,75 | OUTER Ø (mm)6,2 | CABLE WT. (kg/km)65 | COPPER (kg/km)30,0 | Availability On request |
| CORES × SECTION (n×mm²)5×0,75 | OUTER Ø (mm)6,9 | CABLE WT. (kg/km)80 | COPPER (kg/km)37,5 | Availability On request |
| CORES × SECTION (n×mm²)7×0,75 | OUTER Ø (mm)7,6 | CABLE WT. (kg/km)100 | COPPER (kg/km)52,5 | Availability On request |
| CORES × SECTION (n×mm²)18×0,75 | OUTER Ø (mm)12,0 | CABLE WT. (kg/km)245 | COPPER (kg/km)135,0 | Availability On request |
| CORES × SECTION (n×mm²)25×0,75 | OUTER Ø (mm)14,1 | CABLE WT. (kg/km)325 | COPPER (kg/km)187,5 | Availability On request |
| CORES × SECTION (n×mm²)2×1 | OUTER Ø (mm)5,8 | CABLE WT. (kg/km)50 | COPPER (kg/km)20,0 | Availability On request |
| CORES × SECTION (n×mm²)3×1 | OUTER Ø (mm)6,3 | CABLE WT. (kg/km)61 | COPPER (kg/km)30,0 | Availability On request |
| CORES × SECTION (n×mm²)4×1 | OUTER Ø (mm)6,7 | CABLE WT. (kg/km)75 | COPPER (kg/km)40,0 | Availability On request |
| CORES × SECTION (n×mm²)5×1 | OUTER Ø (mm)7,3 | CABLE WT. (kg/km)95 | COPPER (kg/km)50,0 | Availability On request |
| CORES × SECTION (n×mm²)7×1 | OUTER Ø (mm)8,3 | CABLE WT. (kg/km)125 | COPPER (kg/km)70,0 | Availability On request |
| CORES × SECTION (n×mm²)12×1 | OUTER Ø (mm)10,7 | CABLE WT. (kg/km)195 | COPPER (kg/km)120,0 | Availability On request |
| CORES × SECTION (n×mm²)18×1 | OUTER Ø (mm)12,8 | CABLE WT. (kg/km)300 | COPPER (kg/km)180,0 | Availability On request |
| CORES × SECTION (n×mm²)25×1 | OUTER Ø (mm)14,7 | CABLE WT. (kg/km)390 | COPPER (kg/km)250,0 | Availability On request |
| CORES × SECTION (n×mm²)2×1,5 | OUTER Ø (mm)6,6 | CABLE WT. (kg/km)65 | COPPER (kg/km)30,0 | Availability On request |
| CORES × SECTION (n×mm²)3×1,5 | OUTER Ø (mm)6,8 | CABLE WT. (kg/km)80 | COPPER (kg/km)45,0 | Availability On request |
| CORES × SECTION (n×mm²)4×1,5 | OUTER Ø (mm)7,4 | CABLE WT. (kg/km)100 | COPPER (kg/km)60,0 | Availability On request |
| CORES × SECTION (n×mm²)5×1,5 | OUTER Ø (mm)8,3 | CABLE WT. (kg/km)130 | COPPER (kg/km)75,0 | Availability On request |
| CORES × SECTION (n×mm²)7×1,5 | OUTER Ø (mm)9,1 | CABLE WT. (kg/km)160 | COPPER (kg/km)105,0 | Availability On request |
| CORES × SECTION (n×mm²)12×1,5 | OUTER Ø (mm)12,3 | CABLE WT. (kg/km)265 | COPPER (kg/km)180,0 | Availability On request |
| CORES × SECTION (n×mm²)18×1,5 | OUTER Ø (mm)14,7 | CABLE WT. (kg/km)405 | COPPER (kg/km)270,0 | Availability On request |
| CORES × SECTION (n×mm²)25×1,5 | OUTER Ø (mm)17,2 | CABLE WT. (kg/km)550 | COPPER (kg/km)375,0 | Availability On request |
Reference tables
| SECTION (mm²)0,75 | CONDUCTOR Ø (mm)1,1 | DC RESISTANCE (Ω/km)26,0 |
| SECTION (mm²)1 | CONDUCTOR Ø (mm)1,3 | DC RESISTANCE (Ω/km)19,5 |
| SECTION (mm²)1,5 | CONDUCTOR Ø (mm)1,5 | DC RESISTANCE (Ω/km)13,3 |
Construction
ConductorFino Cu uže, klasa 5 / fine Cu rope, cl. 5
InsulationPVC, numerisane žile / numbered cores
StrandingSlojevi optimalnog koraka / layers
SheathPVC TM2, plavi RAL 5015 / blue
Technical data
Voltage300/500 V
Test voltage2000 V
Insul. resistance≥ 20 MΩ·km
Operating temp.-30 … +70 °C
Bending radius4 × D (fiksno)
CPR classEca
Application
For potentially explosive atmospheres, type of protection “i” (intrinsically safe), in measuring and control technology. Blue sheath specially marked per DIN EN 60079-14. Not for underground laying.
Standards
DIN VDE 0285-525-2-51 · DIN VDE 0295 / IEC 60228 cl.5 · DIN EN 60079-14 · DIN VDE 0165-1
Documents
YSLY EB · PDF · 356 KBDownload datasheet (PDF)