YSLYQY
Flexible control cable with PVC inner sheath and steel-wire braid (YSLYQY-JZ/OZ), 300/500 V.
Download datasheet (PDF)
Variants
| CORES × SECTION (n×mm²)2×0,5 | OUTER Ø (mm)7,6 | CABLE WT. (kg/km)92 | Availability On request |
| CORES × SECTION (n×mm²)3×0,5 | OUTER Ø (mm)7,9 | CABLE WT. (kg/km)101 | Availability On request |
| CORES × SECTION (n×mm²)4×0,5 | OUTER Ø (mm)8,5 | CABLE WT. (kg/km)118 | Availability On request |
| CORES × SECTION (n×mm²)5×0,5 | OUTER Ø (mm)9,0 | CABLE WT. (kg/km)134 | Availability On request |
| CORES × SECTION (n×mm²)6×0,5 | OUTER Ø (mm)9,9 | CABLE WT. (kg/km)159 | Availability On request |
| CORES × SECTION (n×mm²)7×0,5 | OUTER Ø (mm)9,9 | CABLE WT. (kg/km)163 | Availability On request |
| CORES × SECTION (n×mm²)8×0,5 | OUTER Ø (mm)10,4 | CABLE WT. (kg/km)173 | Availability On request |
| CORES × SECTION (n×mm²)10×0,5 | OUTER Ø (mm)11,8 | CABLE WT. (kg/km)217 | Availability On request |
| CORES × SECTION (n×mm²)12×0,5 | OUTER Ø (mm)12,1 | CABLE WT. (kg/km)234 | Availability On request |
| CORES × SECTION (n×mm²)14×0,5 | OUTER Ø (mm)12,7 | CABLE WT. (kg/km)259 | Availability On request |
| CORES × SECTION (n×mm²)16×0,5 | OUTER Ø (mm)13,2 | CABLE WT. (kg/km)283 | Availability On request |
| CORES × SECTION (n×mm²)18×0,5 | OUTER Ø (mm)13,7 | CABLE WT. (kg/km)306 | Availability On request |
| CORES × SECTION (n×mm²)19×0,5 | OUTER Ø (mm)13,7 | CABLE WT. (kg/km)310 | Availability On request |
| CORES × SECTION (n×mm²)20×0,5 | OUTER Ø (mm)14,4 | CABLE WT. (kg/km)338 | Availability On request |
| CORES × SECTION (n×mm²)21×0,5 | OUTER Ø (mm)14,4 | CABLE WT. (kg/km)342 | Availability On request |
| CORES × SECTION (n×mm²)24×0,5 | OUTER Ø (mm)15,3 | CABLE WT. (kg/km)384 | Availability On request |
| CORES × SECTION (n×mm²)25×0,5 | OUTER Ø (mm)15,3 | CABLE WT. (kg/km)388 | Availability On request |
| CORES × SECTION (n×mm²)30×0,5 | OUTER Ø (mm)16,7 | CABLE WT. (kg/km)461 | Availability On request |
| CORES × SECTION (n×mm²)2×0,75 | OUTER Ø (mm)8,0 | CABLE WT. (kg/km)104 | Availability On request |
| CORES × SECTION (n×mm²)3×0,75 | OUTER Ø (mm)8,5 | CABLE WT. (kg/km)119 | Availability On request |
| CORES × SECTION (n×mm²)4×0,75 | OUTER Ø (mm)9,0 | CABLE WT. (kg/km)136 | Availability On request |
| CORES × SECTION (n×mm²)5×0,75 | OUTER Ø (mm)9,9 | CABLE WT. (kg/km)165 | Availability On request |
| CORES × SECTION (n×mm²)6×0,75 | OUTER Ø (mm)10,5 | CABLE WT. (kg/km)185 | Availability On request |
| CORES × SECTION (n×mm²)7×0,75 | OUTER Ø (mm)10,5 | CABLE WT. (kg/km)191 | Availability On request |
| CORES × SECTION (n×mm²)8×0,75 | OUTER Ø (mm)11,3 | CABLE WT. (kg/km)210 | Availability On request |
| CORES × SECTION (n×mm²)10×0,75 | OUTER Ø (mm)12,8 | CABLE WT. (kg/km)264 | Availability On request |
| CORES × SECTION (n×mm²)12×0,75 | OUTER Ø (mm)13,1 | CABLE WT. (kg/km)285 | Availability On request |
| CORES × SECTION (n×mm²)14×0,75 | OUTER Ø (mm)13,6 | CABLE WT. (kg/km)312 | Availability On request |
| CORES × SECTION (n×mm²)16×0,75 | OUTER Ø (mm)14,3 | CABLE WT. (kg/km)348 | Availability On request |
| CORES × SECTION (n×mm²)18×0,75 | OUTER Ø (mm)14,9 | CABLE WT. (kg/km)379 | Availability On request |
| CORES × SECTION (n×mm²)19×0,75 | OUTER Ø (mm)14,9 | CABLE WT. (kg/km)385 | Availability On request |
| CORES × SECTION (n×mm²)20×0,75 | OUTER Ø (mm)15,9 | CABLE WT. (kg/km)425 | Availability On request |
| CORES × SECTION (n×mm²)21×0,75 | OUTER Ø (mm)15,9 | CABLE WT. (kg/km)432 | Availability On request |
| CORES × SECTION (n×mm²)24×0,75 | OUTER Ø (mm)17,0 | CABLE WT. (kg/km)493 | Availability On request |
| CORES × SECTION (n×mm²)25×0,75 | OUTER Ø (mm)17,0 | CABLE WT. (kg/km)499 | Availability On request |
| CORES × SECTION (n×mm²)2×1 | OUTER Ø (mm)8,5 | CABLE WT. (kg/km)118 | Availability On request |
| CORES × SECTION (n×mm²)3×1 | OUTER Ø (mm)8,8 | CABLE WT. (kg/km)133 | Availability On request |
| CORES × SECTION (n×mm²)4×1 | OUTER Ø (mm)9,4 | CABLE WT. (kg/km)152 | Availability On request |
| CORES × SECTION (n×mm²)5×1 | OUTER Ø (mm)10,3 | CABLE WT. (kg/km)185 | Availability On request |
| CORES × SECTION (n×mm²)6×1 | OUTER Ø (mm)11,0 | CABLE WT. (kg/km)208 | Availability On request |
| CORES × SECTION (n×mm²)7×1 | OUTER Ø (mm)11,0 | CABLE WT. (kg/km)216 | Availability On request |
| CORES × SECTION (n×mm²)8×1 | OUTER Ø (mm)11,8 | CABLE WT. (kg/km)238 | Availability On request |
| CORES × SECTION (n×mm²)10×1 | OUTER Ø (mm)13,4 | CABLE WT. (kg/km)300 | Availability On request |
| CORES × SECTION (n×mm²)12×1 | OUTER Ø (mm)13,7 | CABLE WT. (kg/km)327 | Availability On request |
| CORES × SECTION (n×mm²)14×1 | OUTER Ø (mm)14,5 | CABLE WT. (kg/km)366 | Availability On request |
| CORES × SECTION (n×mm²)16×1 | OUTER Ø (mm)15,0 | CABLE WT. (kg/km)401 | Availability On request |
| CORES × SECTION (n×mm²)18×1 | OUTER Ø (mm)16,1 | CABLE WT. (kg/km)453 | Availability On request |
| CORES × SECTION (n×mm²)19×1 | OUTER Ø (mm)16,1 | CABLE WT. (kg/km)460 | Availability On request |
| CORES × SECTION (n×mm²)20×1 | OUTER Ø (mm)16,7 | CABLE WT. (kg/km)491 | Availability On request |
| CORES × SECTION (n×mm²)21×1 | OUTER Ø (mm)16,7 | CABLE WT. (kg/km)499 | Availability On request |
| CORES × SECTION (n×mm²)2×1,5 | OUTER Ø (mm)9,0 | CABLE WT. (kg/km)136 | Availability On request |
| CORES × SECTION (n×mm²)3×1,5 | OUTER Ø (mm)9,4 | CABLE WT. (kg/km)155 | Availability On request |
| CORES × SECTION (n×mm²)4×1,5 | OUTER Ø (mm)10,4 | CABLE WT. (kg/km)191 | Availability On request |
| CORES × SECTION (n×mm²)5×1,5 | OUTER Ø (mm)11,2 | CABLE WT. (kg/km)224 | Availability On request |
| CORES × SECTION (n×mm²)6×1,5 | OUTER Ø (mm)11,9 | CABLE WT. (kg/km)255 | Availability On request |
| CORES × SECTION (n×mm²)7×1,5 | OUTER Ø (mm)11,9 | CABLE WT. (kg/km)266 | Availability On request |
| CORES × SECTION (n×mm²)8×1,5 | OUTER Ø (mm)12,8 | CABLE WT. (kg/km)294 | Availability On request |
| CORES × SECTION (n×mm²)10×1,5 | OUTER Ø (mm)14,6 | CABLE WT. (kg/km)372 | Availability On request |
| CORES × SECTION (n×mm²)12×1,5 | OUTER Ø (mm)15,0 | CABLE WT. (kg/km)408 | Availability On request |
| CORES × SECTION (n×mm²)14×1,5 | OUTER Ø (mm)16,0 | CABLE WT. (kg/km)465 | Availability On request |
| CORES × SECTION (n×mm²)16×1,5 | OUTER Ø (mm)16,6 | CABLE WT. (kg/km)511 | Availability On request |
| CORES × SECTION (n×mm²)18×1,5 | OUTER Ø (mm)17,5 | CABLE WT. (kg/km)568 | Availability On request |
| CORES × SECTION (n×mm²)19×1,5 | OUTER Ø (mm)17,5 | CABLE WT. (kg/km)579 | Availability On request |
| CORES × SECTION (n×mm²)2×2,5 | OUTER Ø (mm)10,7 | CABLE WT. (kg/km)193 | Availability On request |
| CORES × SECTION (n×mm²)3×2,5 | OUTER Ø (mm)11,4 | CABLE WT. (kg/km)229 | Availability On request |
| CORES × SECTION (n×mm²)4×2,5 | OUTER Ø (mm)12,1 | CABLE WT. (kg/km)267 | Availability On request |
| CORES × SECTION (n×mm²)5×2,5 | OUTER Ø (mm)13,2 | CABLE WT. (kg/km)318 | Availability On request |
| CORES × SECTION (n×mm²)6×2,5 | OUTER Ø (mm)14,3 | CABLE WT. (kg/km)372 | Availability On request |
| CORES × SECTION (n×mm²)7×2,5 | OUTER Ø (mm)14,3 | CABLE WT. (kg/km)388 | Availability On request |
| CORES × SECTION (n×mm²)8×2,5 | OUTER Ø (mm)15,2 | CABLE WT. (kg/km)425 | Availability On request |
| CORES × SECTION (n×mm²)4×4 | OUTER Ø (mm)13,5 | CABLE WT. (kg/km)354 | Availability On request |
| CORES × SECTION (n×mm²)5×4 | OUTER Ø (mm)14,7 | CABLE WT. (kg/km)425 | Availability On request |
| CORES × SECTION (n×mm²)4×6 | OUTER Ø (mm)15,9 | CABLE WT. (kg/km)498 | Availability On request |
| CORES × SECTION (n×mm²)5×6 | OUTER Ø (mm)17,3 | CABLE WT. (kg/km)597 | Availability On request |
Reference tables
| SECTION (mm²)0,5 | DC RESISTANCE (max.) (Ω/km)39 |
| SECTION (mm²)0,75 | DC RESISTANCE (max.) (Ω/km)26 |
| SECTION (mm²)1 | DC RESISTANCE (max.) (Ω/km)19,5 |
| SECTION (mm²)1,5 | DC RESISTANCE (max.) (Ω/km)13,3 |
| SECTION (mm²)2,5 | DC RESISTANCE (max.) (Ω/km)7,98 |
| SECTION (mm²)4 | DC RESISTANCE (max.) (Ω/km)4,95 |
| SECTION (mm²)6 | DC RESISTANCE (max.) (Ω/km)3,30 |
Construction
ConductorCu uže, klasa 5 / Cu rope, cl. 5
InsulationPVC (TSE K 373)
StrandingŽile u slojevima / cores in layers
Inner sheathPVC
Screen (armour)Pletenica od čeličnih žica / steel wire braid
SheathPVC, RAL 7001 sivi / grey
Technical data
Voltage300/500 V
Test voltage4000 V AC (1 min)
Operating temp.-30 … +70 °C
Bending radius7,5 × D
Transfer imped.250 mΩ/m (30 MHz)
Flame testEN 60332-1-2
Application
Control cable per TSE K 373 for electronic control systems, measurement and monitoring, and industrial electronics. The steel braid adds mechanical protection. Not for outdoor use or direct burial.
Standards
TSE K 373 · EN / IEC 60228 · DIN EN 60332-1-2 · EN 50575 (CPR)
Documents
YSLYQY · PDF · 434 KBDownload datasheet (PDF)