FR-N1XD4-AR_FR-N1XD9-AR

FR-N1XD4-AR (X00-A) and FR-N1XD9-AR (X00/0-A), XLPE insulated aerial bundled cables 0.6/1 kV.

Download datasheet (PDF)
FR-N1XD4-AR (X00-A) and FR-N1XD9-AR (X00/0-A), XLPE insulated aerial bundled cables 0.6/1 kV.

Variants

CROSS-SECTION (mm²)16WIRES (No.)7CONDUCTOR Ø (mm)4,6-5,1RESISTANCE 20 °C (Ω/km)1,910AMPACITY AIR 30 °C (A)93SHORT-CIRCUIT (kA)1,5INSULATION (mm)1,2INSULATED CORE Ø (mm)7,0-7,8Availability
On request
CROSS-SECTION (mm²)25WIRES (No.)7CONDUCTOR Ø (mm)5,8-6,3RESISTANCE 20 °C (Ω/km)1,200AMPACITY AIR 30 °C (A)112SHORT-CIRCUIT (kA)2,34INSULATION (mm)1,4INSULATED CORE Ø (mm)8,6-9,4Availability
On request
CROSS-SECTION (mm²)35WIRES (No.)7CONDUCTOR Ø (mm)6,8-7,3RESISTANCE 20 °C (Ω/km)0,868AMPACITY AIR 30 °C (A)131SHORT-CIRCUIT (kA)3,25INSULATION (mm)1,6INSULATED CORE Ø (mm)10,0-10,9Availability
On request
CROSS-SECTION (mm²)50WIRES (No.)7CONDUCTOR Ø (mm)7,9-8,4RESISTANCE 20 °C (Ω/km)0,641AMPACITY AIR 30 °C (A)168SHORT-CIRCUIT (kA)4,67INSULATION (mm)1,6INSULATED CORE Ø (mm)11,1-12,0Availability
On request
CROSS-SECTION (mm²)70WIRES (No.)12CONDUCTOR Ø (mm)9,7-10,2RESISTANCE 20 °C (Ω/km)0,443AMPACITY AIR 30 °C (A)213SHORT-CIRCUIT (kA)6,54INSULATION (mm)1,8INSULATED CORE Ø (mm)13,3-14,2Availability
On request
CROSS-SECTION (mm²)95WIRES (No.)19CONDUCTOR Ø (mm)11-12RESISTANCE 20 °C (Ω/km)0,320AMPACITY AIR 30 °C (A)258SHORT-CIRCUIT (kA)8,88INSULATION (mm)1,8INSULATED CORE Ø (mm)14,6-15,7Availability
On request
CROSS-SECTION (mm²)120WIRES (No.)19CONDUCTOR Ø (mm)12-13,1RESISTANCE 20 °C (Ω/km)0,253AMPACITY AIR 30 °C (A)300SHORT-CIRCUIT (kA)11,22INSULATION (mm)1,8INSULATED CORE Ø (mm)15,6-16,7Availability
On request
CROSS-SECTION (mm²)150WIRES (No.)19CONDUCTOR Ø (mm)13,9-15RESISTANCE 20 °C (Ω/km)0,206AMPACITY AIR 30 °C (A)344SHORT-CIRCUIT (kA)14,02INSULATION (mm)1,7INSULATED CORE Ø (mm)17,3-18,6Availability
On request

Prices for registered business customers · Registration takes 2 minutes

Sign inRegister

Reference tables

CROSS-SECTION (mm²)54,6WIRES (No.)7MESSENGER Ø (mm)9,20-9,60RESISTANCE 20 °C (Ω/km)0,630BREAKING LOAD (daN)1660INSULATION (mm)1,6INSULATED CORE Ø (mm)12,30-13,00
CROSS-SECTION (mm²)70WIRES (No.)7MESSENGER Ø (mm)10,00-10,20RESISTANCE 20 °C (Ω/km)0,500BREAKING LOAD (daN)2050INSULATION (mm)1,5INSULATED CORE Ø (mm)12,90-13,60
CROSS-SECTION (mm²)71,5WIRES (No.)7MESSENGER Ø (mm)9,2RESISTANCE 20 °C (Ω/km)0,628BREAKING LOAD (daN)2050INSULATION (mm)1,6INSULATED CORE Ø (mm)12,2-13,3
CROSS-SECTION (mm²)95WIRES (No.)7MESSENGER Ø (mm)12,20-12,90RESISTANCE 20 °C (Ω/km)0,340BREAKING LOAD (daN)2750INSULATION (mm)1,6INSULATED CORE Ø (mm)15,30-16,30

PRODUCT (—)FR-N1XD4-AR 2x16MAX. LAY LENGTH (mm)300APPROX. OUTER DIAM. (mm)15,0APPROX. CABLE WEIGHT (kg/km)137
PRODUCT (—)FR-N1XD4-AR 4x16MAX. LAY LENGTH (mm)350APPROX. OUTER DIAM. (mm)18,0APPROX. CABLE WEIGHT (kg/km)270
PRODUCT (—)FR-N1XD4-AR 5x16MAX. LAY LENGTH (mm)400APPROX. OUTER DIAM. (mm)19,4APPROX. CABLE WEIGHT (kg/km)337
PRODUCT (—)FR-N1XD4-AR 2x25MAX. LAY LENGTH (mm)350APPROX. OUTER DIAM. (mm)18,4APPROX. CABLE WEIGHT (kg/km)214
PRODUCT (—)FR-N1XD4-AR 4x25MAX. LAY LENGTH (mm)430APPROX. OUTER DIAM. (mm)22,2APPROX. CABLE WEIGHT (kg/km)431
PRODUCT (—)FR-N1XD4-AR 4x35MAX. LAY LENGTH (mm)450APPROX. OUTER DIAM. (mm)23,7APPROX. CABLE WEIGHT (kg/km)550
PRODUCT (—)FR-N1XD4-AR 4x50MAX. LAY LENGTH (mm)480APPROX. OUTER DIAM. (mm)27,5APPROX. CABLE WEIGHT (kg/km)740
PRODUCT (—)FR-N1XD4-AR 4x70MAX. LAY LENGTH (mm)550APPROX. OUTER DIAM. (mm)31,9APPROX. CABLE WEIGHT (kg/km)1000
PRODUCT (—)FR-N1XD4-AR 4x95MAX. LAY LENGTH (mm)600APPROX. OUTER DIAM. (mm)37,0APPROX. CABLE WEIGHT (kg/km)1334
PRODUCT (—)FR-N1XD9-AR 3x35+54,6MAX. LAY LENGTH (mm)760APPROX. OUTER DIAM. (mm)24,6APPROX. CABLE WEIGHT (kg/km)370
PRODUCT (—)FR-N1XD9-AR 3x35+70MAX. LAY LENGTH (mm)760APPROX. OUTER DIAM. (mm)29,8APPROX. CABLE WEIGHT (kg/km)688
PRODUCT (—)FR-N1XD9-AR 3x35+70+2x16MAX. LAY LENGTH (mm)760APPROX. OUTER DIAM. (mm)29,8APPROX. CABLE WEIGHT (kg/km)825
PRODUCT (—)FR-N1XD9-AR 3x50+54,6MAX. LAY LENGTH (mm)850APPROX. OUTER DIAM. (mm)33,1APPROX. CABLE WEIGHT (kg/km)782
PRODUCT (—)FR-N1XD9-AR 3x50+70MAX. LAY LENGTH (mm)850APPROX. OUTER DIAM. (mm)33,1APPROX. CABLE WEIGHT (kg/km)809
PRODUCT (—)FR-N1XD9-AR 3x50+70+2x16MAX. LAY LENGTH (mm)850APPROX. OUTER DIAM. (mm)33,1APPROX. CABLE WEIGHT (kg/km)945
PRODUCT (—)FR-N1XD9-AR 3x70+54,6MAX. LAY LENGTH (mm)980APPROX. OUTER DIAM. (mm)38,1APPROX. CABLE WEIGHT (kg/km)1020
PRODUCT (—)FR-N1XD9-AR 3x70+54,6+1x16MAX. LAY LENGTH (mm)980APPROX. OUTER DIAM. (mm)38,1APPROX. CABLE WEIGHT (kg/km)1087
PRODUCT (—)FR-N1XD9-AR 3x70+70MAX. LAY LENGTH (mm)980APPROX. OUTER DIAM. (mm)38,6APPROX. CABLE WEIGHT (kg/km)1044
PRODUCT (—)FR-N1XD9-AR 3x70+70/12MAX. LAY LENGTH (mm)980APPROX. OUTER DIAM. (mm)39,5APPROX. CABLE WEIGHT (kg/km)1125
PRODUCT (—)FR-N1XD9-AR 3x70+70+2x16MAX. LAY LENGTH (mm)980APPROX. OUTER DIAM. (mm)38,6APPROX. CABLE WEIGHT (kg/km)1181
PRODUCT (—)FR-N1XD9-AR 3x70+70+2x25MAX. LAY LENGTH (mm)980APPROX. OUTER DIAM. (mm)40,0APPROX. CABLE WEIGHT (kg/km)1253
PRODUCT (—)FR-N1XD9-AR 3x95+70MAX. LAY LENGTH (mm)1100APPROX. OUTER DIAM. (mm)42,0APPROX. CABLE WEIGHT (kg/km)1289
PRODUCT (—)FR-N1XD9-AR 3x95+70/12MAX. LAY LENGTH (mm)1100APPROX. OUTER DIAM. (mm)43,5APPROX. CABLE WEIGHT (kg/km)1370

Construction

Phase conductorKompaktovano Al uže, klasa 2
MessengerKompaktovano Al ili Al-legura, klasa 2
InsulationXLPE smeša / XLPE compound
AssemblySamonoseći snop / Self-supporting bundle

Technical data

CPR classFca
Test voltage4 kV
Rated voltage0,6/1 kV
Conductor90 °C
Short-circuit250 °C

Application

For low-voltage overhead distribution networks in urban, suburban and rural areas, supplying remote facilities and villages, and above-ground house connections.

Standards

HD626 S1

HD 626 S1 · NF C33-209 · JUS N.C5.250

Documents

FR-N1XD4-AR_FR-N1XD9-AR · PDF · 415 KBDownload datasheet (PDF)