I-D(ZN)H
Indoor fibre-optic cable with a central loose tube (bundle) to DIN VDE 0888; metal-free (ZN) construction, aramid strength members, halogen-free FRNC sheath (yellow); 4–60 fibres.
Download datasheet (PDF)
Characteristics
| CHARACTERISTICBroj vlakana / Fibre count | VALUE4–60 | UNIT— |
| CHARACTERISTICSpoljašnji prečnik / Outer diameter | VALUE8,0–13,5 | UNITmm |
| CHARACTERISTICMaks. zatezna sila / Max. tensile force | VALUE1200–3000 | UNITN |
| CHARACTERISTICMin. poluprečnik savijanja / Min. bending radius | VALUE120–200 | UNITmm |
| CHARACTERISTICMaks. poprečni pritisak / Max. transverse pressure | VALUE150–200 | UNITN/cm |
| CHARACTERISTICPožarno opterećenje / Fire load | VALUE1,50–2,20 | UNITMJ/m |
| CHARACTERISTICMasa kabla / Cable weight | VALUE65–170 | UNITkg/km |
| CHARACTERISTICRadna temperatura / Operating temperature | VALUE−20…+60 | UNIT°C |
| CHARACTERISTICTemperatura polaganja / Installation temperature | VALUE−5…+50 | UNIT°C |
Construction
Optical fibreMM G50/125 OM2, MM G62,5/125 OM1 ili SM E9/125 G.652.D
Loose tubecentralna cev (Bündelader) / central bundle tube
Strength memberaramid, nemetalni (ZN) / aramid, non-metallic (ZN)
Sheathbezhalogeni FRNC, žut / halogen-free FRNC, yellow
Technical data
Fibre typeMM OM2·OM1 / SM
Fibre count4–60
Tensile1200–3000 N
Bending120–200 mm
Temp.−20…+60 °C
Std.DIN VDE 0888
Application
Indoor cabling of buildings and installations. The halogen-free version is especially suited to high-rise buildings, hospitals and department stores, high-asset sites (power stations, data centres) and high-security facilities (metro, control centres).
Standards
IEC60754-2
IEC60332-1-2
IEC61034
DIN VDE 0888 · EN 50267-2-3 · IEC 60754-2 · IEC 60332-1-2 · IEC 61034 · ITU-T G.652.D
Documents
I-D(ZN)H · PDF · 319 KBDownload datasheet (PDF)