LiHCH
Halogen-free screened signal cable (LiHCH) with HFFR insulation and sheath and Cu braid — for indoor EMC applications.
Download datasheet (PDF)
Variants
| CORES × SECTION (n×mm²)2×0,22 | OUTER Ø (mm)4,10 | COPPER WT. (kg/km)8 | CABLE WT. (kg/km)22 | Availability On request |
| CORES × SECTION (n×mm²)3×0,22 | OUTER Ø (mm)4,30 | COPPER WT. (kg/km)10 | CABLE WT. (kg/km)26 | Availability On request |
| CORES × SECTION (n×mm²)4×0,22 | OUTER Ø (mm)4,60 | COPPER WT. (kg/km)12 | CABLE WT. (kg/km)30 | Availability On request |
| CORES × SECTION (n×mm²)5×0,22 | OUTER Ø (mm)5,00 | COPPER WT. (kg/km)15 | CABLE WT. (kg/km)36 | Availability On request |
| CORES × SECTION (n×mm²)6×0,22 | OUTER Ø (mm)5,30 | COPPER WT. (kg/km)17 | CABLE WT. (kg/km)40 | Availability On request |
| CORES × SECTION (n×mm²)7×0,22 | OUTER Ø (mm)5,30 | COPPER WT. (kg/km)19 | CABLE WT. (kg/km)43 | Availability On request |
| CORES × SECTION (n×mm²)8×0,22 | OUTER Ø (mm)5,70 | COPPER WT. (kg/km)22 | CABLE WT. (kg/km)49 | Availability On request |
| CORES × SECTION (n×mm²)10×0,22 | OUTER Ø (mm)6,50 | COPPER WT. (kg/km)26 | CABLE WT. (kg/km)58 | Availability On request |
| CORES × SECTION (n×mm²)12×0,22 | OUTER Ø (mm)6,70 | COPPER WT. (kg/km)30 | CABLE WT. (kg/km)66 | Availability On request |
| CORES × SECTION (n×mm²)2×0,25 | OUTER Ø (mm)4,20 | COPPER WT. (kg/km)9 | CABLE WT. (kg/km)23 | Availability On request |
| CORES × SECTION (n×mm²)3×0,25 | OUTER Ø (mm)4,40 | COPPER WT. (kg/km)12 | CABLE WT. (kg/km)28 | Availability On request |
| CORES × SECTION (n×mm²)4×0,25 | OUTER Ø (mm)4,70 | COPPER WT. (kg/km)14 | CABLE WT. (kg/km)33 | Availability On request |
| CORES × SECTION (n×mm²)5×0,25 | OUTER Ø (mm)5,10 | COPPER WT. (kg/km)17 | CABLE WT. (kg/km)38 | Availability On request |
| CORES × SECTION (n×mm²)6×0,25 | OUTER Ø (mm)5,50 | COPPER WT. (kg/km)20 | CABLE WT. (kg/km)44 | Availability On request |
| CORES × SECTION (n×mm²)7×0,25 | OUTER Ø (mm)5,50 | COPPER WT. (kg/km)22 | CABLE WT. (kg/km)47 | Availability On request |
| CORES × SECTION (n×mm²)8×0,25 | OUTER Ø (mm)5,90 | COPPER WT. (kg/km)25 | CABLE WT. (kg/km)53 | Availability On request |
| CORES × SECTION (n×mm²)10×0,25 | OUTER Ø (mm)6,70 | COPPER WT. (kg/km)31 | CABLE WT. (kg/km)64 | Availability On request |
| CORES × SECTION (n×mm²)12×0,25 | OUTER Ø (mm)6,90 | COPPER WT. (kg/km)36 | CABLE WT. (kg/km)73 | Availability On request |
| CORES × SECTION (n×mm²)2×0,34 | OUTER Ø (mm)4,40 | COPPER WT. (kg/km)11 | CABLE WT. (kg/km)26 | Availability On request |
| CORES × SECTION (n×mm²)3×0,34 | OUTER Ø (mm)4,60 | COPPER WT. (kg/km)15 | CABLE WT. (kg/km)32 | Availability On request |
| CORES × SECTION (n×mm²)4×0,34 | OUTER Ø (mm)5,00 | COPPER WT. (kg/km)19 | CABLE WT. (kg/km)39 | Availability On request |
| CORES × SECTION (n×mm²)5×0,34 | OUTER Ø (mm)5,40 | COPPER WT. (kg/km)22 | CABLE WT. (kg/km)45 | Availability On request |
| CORES × SECTION (n×mm²)6×0,34 | OUTER Ø (mm)5,80 | COPPER WT. (kg/km)26 | CABLE WT. (kg/km)51 | Availability On request |
| CORES × SECTION (n×mm²)7×0,34 | OUTER Ø (mm)5,80 | COPPER WT. (kg/km)29 | CABLE WT. (kg/km)56 | Availability On request |
| CORES × SECTION (n×mm²)8×0,34 | OUTER Ø (mm)6,20 | COPPER WT. (kg/km)33 | CABLE WT. (kg/km)63 | Availability On request |
| CORES × SECTION (n×mm²)10×0,34 | OUTER Ø (mm)7,10 | COPPER WT. (kg/km)41 | CABLE WT. (kg/km)77 | Availability On request |
| CORES × SECTION (n×mm²)12×0,34 | OUTER Ø (mm)7,30 | COPPER WT. (kg/km)48 | CABLE WT. (kg/km)87 | Availability On request |
| CORES × SECTION (n×mm²)2×0,5 | OUTER Ø (mm)5,10 | COPPER WT. (kg/km)14 | CABLE WT. (kg/km)33 | Availability On request |
| CORES × SECTION (n×mm²)3×0,5 | OUTER Ø (mm)5,40 | COPPER WT. (kg/km)19 | CABLE WT. (kg/km)42 | Availability On request |
| CORES × SECTION (n×mm²)4×0,5 | OUTER Ø (mm)5,80 | COPPER WT. (kg/km)24 | CABLE WT. (kg/km)51 | Availability On request |
| CORES × SECTION (n×mm²)5×0,5 | OUTER Ø (mm)6,30 | COPPER WT. (kg/km)28 | CABLE WT. (kg/km)59 | Availability On request |
| CORES × SECTION (n×mm²)6×0,5 | OUTER Ø (mm)6,80 | COPPER WT. (kg/km)33 | CABLE WT. (kg/km)68 | Availability On request |
| CORES × SECTION (n×mm²)7×0,5 | OUTER Ø (mm)6,80 | COPPER WT. (kg/km)38 | CABLE WT. (kg/km)76 | Availability On request |
| CORES × SECTION (n×mm²)8×0,5 | OUTER Ø (mm)7,30 | COPPER WT. (kg/km)43 | CABLE WT. (kg/km)85 | Availability On request |
| CORES × SECTION (n×mm²)10×0,5 | OUTER Ø (mm)8,70 | COPPER WT. (kg/km)53 | CABLE WT. (kg/km)108 | Availability On request |
| CORES × SECTION (n×mm²)12×0,5 | OUTER Ø (mm)9,00 | COPPER WT. (kg/km)62 | CABLE WT. (kg/km)124 | Availability On request |
| CORES × SECTION (n×mm²)2×0,75 | OUTER Ø (mm)5,50 | COPPER WT. (kg/km)19 | CABLE WT. (kg/km)40 | Availability On request |
| CORES × SECTION (n×mm²)3×0,75 | OUTER Ø (mm)5,80 | COPPER WT. (kg/km)26 | CABLE WT. (kg/km)51 | Availability On request |
| CORES × SECTION (n×mm²)4×0,75 | OUTER Ø (mm)6,30 | COPPER WT. (kg/km)33 | CABLE WT. (kg/km)63 | Availability On request |
| CORES × SECTION (n×mm²)5×0,75 | OUTER Ø (mm)6,80 | COPPER WT. (kg/km)40 | CABLE WT. (kg/km)75 | Availability On request |
| CORES × SECTION (n×mm²)6×0,75 | OUTER Ø (mm)7,40 | COPPER WT. (kg/km)47 | CABLE WT. (kg/km)87 | Availability On request |
| CORES × SECTION (n×mm²)7×0,75 | OUTER Ø (mm)7,40 | COPPER WT. (kg/km)53 | CABLE WT. (kg/km)96 | Availability On request |
| CORES × SECTION (n×mm²)8×0,75 | OUTER Ø (mm)8,00 | COPPER WT. (kg/km)60 | CABLE WT. (kg/km)108 | Availability On request |
| CORES × SECTION (n×mm²)10×0,75 | OUTER Ø (mm)9,50 | COPPER WT. (kg/km)75 | CABLE WT. (kg/km)138 | Availability On request |
| CORES × SECTION (n×mm²)12×0,75 | OUTER Ø (mm)9,80 | COPPER WT. (kg/km)89 | CABLE WT. (kg/km)159 | Availability On request |
| CORES × SECTION (n×mm²)2×1,0 | OUTER Ø (mm)5,90 | COPPER WT. (kg/km)24 | CABLE WT. (kg/km)48 | Availability On request |
| CORES × SECTION (n×mm²)3×1,0 | OUTER Ø (mm)6,30 | COPPER WT. (kg/km)33 | CABLE WT. (kg/km)62 | Availability On request |
| CORES × SECTION (n×mm²)4×1,0 | OUTER Ø (mm)6,80 | COPPER WT. (kg/km)42 | CABLE WT. (kg/km)76 | Availability On request |
| CORES × SECTION (n×mm²)5×1,0 | OUTER Ø (mm)7,40 | COPPER WT. (kg/km)51 | CABLE WT. (kg/km)90 | Availability On request |
| CORES × SECTION (n×mm²)6×1,0 | OUTER Ø (mm)8,00 | COPPER WT. (kg/km)60 | CABLE WT. (kg/km)105 | Availability On request |
| CORES × SECTION (n×mm²)7×1,0 | OUTER Ø (mm)8,00 | COPPER WT. (kg/km)69 | CABLE WT. (kg/km)118 | Availability On request |
| CORES × SECTION (n×mm²)8×1,0 | OUTER Ø (mm)8,90 | COPPER WT. (kg/km)78 | CABLE WT. (kg/km)137 | Availability On request |
| CORES × SECTION (n×mm²)10×1,0 | OUTER Ø (mm)10,30 | COPPER WT. (kg/km)97 | CABLE WT. (kg/km)168 | Availability On request |
| CORES × SECTION (n×mm²)12×1,0 | OUTER Ø (mm)10,70 | COPPER WT. (kg/km)116 | CABLE WT. (kg/km)196 | Availability On request |
| CORES × SECTION (n×mm²)2×1,5 | OUTER Ø (mm)6,70 | COPPER WT. (kg/km)33 | CABLE WT. (kg/km)62 | Availability On request |
| CORES × SECTION (n×mm²)3×1,5 | OUTER Ø (mm)7,10 | COPPER WT. (kg/km)46 | CABLE WT. (kg/km)82 | Availability On request |
| CORES × SECTION (n×mm²)4×1,5 | OUTER Ø (mm)7,70 | COPPER WT. (kg/km)59 | CABLE WT. (kg/km)101 | Availability On request |
| CORES × SECTION (n×mm²)5×1,5 | OUTER Ø (mm)8,70 | COPPER WT. (kg/km)72 | CABLE WT. (kg/km)126 | Availability On request |
| CORES × SECTION (n×mm²)6×1,5 | OUTER Ø (mm)9,40 | COPPER WT. (kg/km)86 | CABLE WT. (kg/km)148 | Availability On request |
| CORES × SECTION (n×mm²)7×1,5 | OUTER Ø (mm)9,40 | COPPER WT. (kg/km)98 | CABLE WT. (kg/km)165 | Availability On request |
| CORES × SECTION (n×mm²)8×1,5 | OUTER Ø (mm)10,20 | COPPER WT. (kg/km)111 | CABLE WT. (kg/km)186 | Availability On request |
| CORES × SECTION (n×mm²)10×1,5 | OUTER Ø (mm)12,10 | COPPER WT. (kg/km)138 | CABLE WT. (kg/km)235 | Availability On request |
| CORES × SECTION (n×mm²)12×1,5 | OUTER Ø (mm)12,50 | COPPER WT. (kg/km)165 | CABLE WT. (kg/km)274 | Availability On request |
| CORES × SECTION (n×mm²)2×2,5 | OUTER Ø (mm)7,60 | COPPER WT. (kg/km)49 | CABLE WT. (kg/km)84 | Availability On request |
| CORES × SECTION (n×mm²)3×2,5 | OUTER Ø (mm)8,30 | COPPER WT. (kg/km)70 | CABLE WT. (kg/km)117 | Availability On request |
| CORES × SECTION (n×mm²)4×2,5 | OUTER Ø (mm)9,00 | COPPER WT. (kg/km)91 | CABLE WT. (kg/km)147 | Availability On request |
| CORES × SECTION (n×mm²)5×2,5 | OUTER Ø (mm)9,90 | COPPER WT. (kg/km)113 | CABLE WT. (kg/km)179 | Availability On request |
| CORES × SECTION (n×mm²)6×2,5 | OUTER Ø (mm)11,00 | COPPER WT. (kg/km)134 | CABLE WT. (kg/km)215 | Availability On request |
| CORES × SECTION (n×mm²)7×2,5 | OUTER Ø (mm)11,00 | COPPER WT. (kg/km)154 | CABLE WT. (kg/km)241 | Availability On request |
| CORES × SECTION (n×mm²)8×2,5 | OUTER Ø (mm)11,90 | COPPER WT. (kg/km)176 | CABLE WT. (kg/km)273 | Availability On request |
| CORES × SECTION (n×mm²)10×2,5 | OUTER Ø (mm)14,10 | COPPER WT. (kg/km)219 | CABLE WT. (kg/km)344 | Availability On request |
| CORES × SECTION (n×mm²)12×2,5 | OUTER Ø (mm)14,60 | COPPER WT. (kg/km)262 | CABLE WT. (kg/km)403 | Availability On request |
Reference tables
| SECTION (mm²)0,22 | MAX. DC RESIST. (Ω/km)96 | MAX. CAPACITANCE (nF/km)120 | TEST VOLTAGE (V AC)1200 |
| SECTION (mm²)0,25 | MAX. DC RESIST. (Ω/km)79 | MAX. CAPACITANCE (nF/km)120 | TEST VOLTAGE (V AC)1200 |
| SECTION (mm²)0,34 | MAX. DC RESIST. (Ω/km)53 | MAX. CAPACITANCE (nF/km)120 | TEST VOLTAGE (V AC)1200 |
| SECTION (mm²)0,50 | MAX. DC RESIST. (Ω/km)39 | MAX. CAPACITANCE (nF/km)150 | TEST VOLTAGE (V AC)1200 |
| SECTION (mm²)0,75 | MAX. DC RESIST. (Ω/km)26 | MAX. CAPACITANCE (nF/km)150 | TEST VOLTAGE (V AC)1200 |
| SECTION (mm²)1,0 | MAX. DC RESIST. (Ω/km)19,5 | MAX. CAPACITANCE (nF/km)150 | TEST VOLTAGE (V AC)1200 |
| SECTION (mm²)1,5 | MAX. DC RESIST. (Ω/km)13,3 | MAX. CAPACITANCE (nF/km)150 | TEST VOLTAGE (V AC)2500 |
| SECTION (mm²)2,5 | MAX. DC RESIST. (Ω/km)7,98 | MAX. CAPACITANCE (nF/km)150 | TEST VOLTAGE (V AC)2500 |
Construction
ConductorCu uže kl. 5 (0,22–0,34: kl. 2)
InsulationHFFR (EN 50290-2-26); DIN 47100
StrandingŽile u slojevima / cores in layers
WrappingPES traka / polyester tape
ScreenKalajisana Cu pletenica / tinned Cu braid
SheathHFFR (EN 50290-2-27), sivi RAL 7001
Technical data
Operating voltage300/500 V
Test voltage1,2 / 2,5 kV AC (1 min)
Impedance≈ 78 Ω
Inductance≈ 0,65 mH/km
Operating temp.-30 … +70 °C
Bending radius7,5 × D
Application
Signal and control cable for industrial electronics, office machines, computers, indoor communication, audio and security systems; LSZH — for densely occupied areas. Not for outdoor use or direct burial.
Standards
TS 13755 · DIN VDE 0812
Documents
LiHCH · PDF · 454 KBDownload datasheet (PDF)